Onduleurs Delta

Appareils pris en charge

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Delta RPI M6/M8/M10/M12/M15A/M20A/M30
H3/H5/H3A/H4A/H5A (non testé)
M6A/M8A/M10A/M50A/M30A (non testé)

Câblage

Le SmartgridOne Controller et les onduleurs Delta communiquent via RS485.

RS485

Câblage Delta
Configurationoptions
Baudrate2400 / 4800 / 9600 / 19200 (par défaut) / 38400
Bits de données8
ParitéAucune
Bits d'arrêt1

Configuration

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.