GerätePV hybrid and battery inverters
iWell Cube Batterie
Unterstützte Geräte
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| iWell Cube Batterie (Experimentell) | Cube Serie | ✅ | ❌ | ✅ |

Verkabelung
Die SmartgridOne Controller kommuniziert mit dem iWell Cube Batteriesystem über Modbus TCP (Ethernet).
Schließen Sie den Ethernet (LAN) Port des Batteriesystems an dasselbe Netzwerk wie die SmartgridOne Controller an.
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Ethernet (TCP/IP) Port | RS485 A | RS485_POS | RS485 A | TX+ |
| Port-Nummer | RS485 B | RS485_NEG | RS485 B | TX- |
| Verbindungstyp | RS GND | GND | Not available | G |
Tip
Stellen Sie sicher, dass sowohl die SmartgridOne Controller als auch die iWell Cube Batterie im gleichen IP-Subnetz sind
(z.B. 192.168.1.xxx) und über den Port 1025 kommunizieren können.
Warning
Die iWell Cube Modbus TCP-Schnittstelle ist nur aktiv, wenn das Batteriesystem eingeschaltet und initialisiert ist.
Verbinden Sie sich nicht mit inaktiven Einheiten oder während Firmware-Updates.