Pular para o conteúdo principal
logo

Inversores Hypontech

Dispositivos Suportados

Device TypeVariantsRS485
Inversor PV Ongrid, 1-FaseHPK 1000/1500/2000/2500/3000, HPS 3000D/3680D/4000D/5000D/6000D, HPS 3000P/3680P/4000P/5000P/6000P
Inversor PV Ongrid, 3-FaseHPT 3000P/4000P/5000P/6000P/8000P/10000P/12000P/15000P, HPT 15KP/20KP/25KP/30KP, HPT 15K/17K/20K/22K/25K, HPT 30K/33K/36K/40K/50K, HPT 60K/70K/80K
Inversor HíbridoHES 3000/3680/4000/5000/6000, HHS 3000/3680/4000/5000/6000, HHT 5000/6000/8000/10000/12000/15000
info

Esta integração não foi testada com todos os dispositivos listados acima, no entanto, como todos eles utilizam o mesmo protocolo de comunicação, devem funcionar sem problemas.

Fiação

O SmartgridOne Controller e os inversores Hypontech se comunicam via RS485.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485A (Pino 3) RS485 ARS485_POSRS485 ATX+
RS485B (Pino 4) RS485 BRS485_NEGRS485 BTX-
N/A RS GNDGNDNot availableG
Fiação Hypontech
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.