Skip to main content
Itho-Daalderop

Itho-Daalderop Heatpump

Supported Devices

Device TypeModbus TCP (Ethernet)RS485
Itho-Daalderop heatpump
warning

Control is only possible using Boost or Block. Specific Wattage control is not supported!

Connection

The communication between the SmartgridOne Controller and the Itho-Daalderop heatpump operates via RS485.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
A RS485 ARS485_POSRS485 ATX+
B RS485 BRS485_NEGRS485 BTX-
GND (if available) RS GNDGNDNot availableG