SmartgridOne logo
SmartgridOne logo
SnabbstartInstallationNätverkKabeldragning och anslutningsriktlinjerApp
ÖversiktNya integrationer
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, hybrida och batteriomvandlareAPsystemsAteps BatteriBeauventC-BatteriCellpowerChisageDanfossDeltaDET Power PV, Hybrid och BatteriinverterDEYEDiehl-AkoDMEGC VäxelriktareDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP UtrustningESY-växelriktareFortonaFraxFroniusGoodWeGotionGrönare / AlfenHiteHithiumHypontechiWellJinkoKacoKehuaKostalMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcelSocomecSolarlogSolarMaxSolarwattSolaxSolintegSolplanetSunwaytechSunwodaSus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextXantrexZeversolar
Autarco
Solis
SpecifikationerStatus LED-lamporKontrollera svarstidVideohandledningarCertifikatLicensSäkerhet, underhåll och juridiska meddelanden
EnheterPV hybrid and battery inverters

Ritar-batterier och omvandlare

Ritar

Stödda Enheter

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Enercube100kW/200kWh✅✅✅

Anslutning

Kommunikationen mellan SmartgridOne och batteriet sker via Modbus TCP.

Ethernet

För korrekt ethernetkabling: Följ riktlinjerna för ethernetkablning.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
ARS485 ARS485_POSRS485 ATX+
BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Renon

Previous Page

SAJ

Next Page

On this page

Stödda EnheterAnslutningEthernetRS485