a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybride en BatterijomvormersAPsystemsAteps batterijBeauventC-BatterijCellpowerChisageDanfossDeltaDET Power PV, Hybride en Accu OmvormersDEYEDiehl-AkoDMEGC OmvormersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP ApparatuurESY OmvormersFortonaFraxFroniusGoodWeGotionGreener / AlfenHiteHithiumHypontechiWellJinkoKacoKehuaKostalMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRenoverenRegitecRenonRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcelSocomecSolarlogSolarMaxSolarwattSolaxSolintegSolplanetSunwaytechSunwodaSus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextXantrexZeversolar
Autarco
Solis
Solis Netgekoppelde Omvormers
Solis Hybride Omvormers
3t10K-HVES-G5 BekabelingS-Serie-Hybride
SpecificatiesStatus-LEDsControleer responsetijdVideo-instructiesCertificatenLicentieVeiligheid, onderhoud en juridische kennisgevingen
ApparatenPV hybrid and battery invertersSolisSolis Hybride Omvormers
logo

Solis S-Series Hybrid Omvormers

Bekabeling

De RS485-verbinding wordt gemaakt via de 16-pins COM-connector aan de onderkant van de omvormer.

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 IN ARS485 ARS485_POSRS485 ATX+
RS485 IN BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Afbeelding

Configuratie

RS485

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Standaard is de omvormer ingesteld op adres 1. Dit kan worden veranderd via het display van de omvormer. U kunt de procedure vinden in hoofdstuk 7.3.2 van de handleiding.