Stödda enheter
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| H3 (Non-Pro, Non-Smart): → ❗Se notis nedan ❗ | ❌ | ✅ | ❗(se nedan) | Master: 2.05, Manager: 1.85 (*) |
| H3 AIO (All-In-One) | ✅ | ❌ | Master: 1.33, Manager: 1.37 (*) |
| Device Type | Modbus TCP (Ethernet) | RS485 | Curtailment | Minimum device firmware version |
|---|---|---|---|---|
| H3 (Non-Pro, Non-Smart): → ❗Se notis nedan ❗ | ❌ | ✅ | ❗(se nedan) | Master: 2.05, Manager: 1.85 (*) |
| H3 AIO (All-In-One) | ✅ | ❌ | Master: 1.33, Manager: 1.37 (*) |
| H3-Smart | ⌛ (pågående utveckling) | Master: 1.25, Manager: 1.14 (*) |
| H3-Pro | Master: 1.62, Manager: 1.34 (*) |
| H1 | (experimentellt, kräver testning) | Master: 1.70, Manager: 1.78 (*) |
| H1-G2 | ⌛ (pågående utveckling) | Master: 1.40, Manager: 1.54 (*) |
| P3-SH | ✅ (experimentellt) | ✅ (experimentellt) | Master: 1.62, Manager: 1.34 (*) |
H3 (Non-Pro, Non-Smart) använder olika kommunikationsprotokoll beroende på omvandlarens 'master version' och 'manager version'. Välj motsvarande integration baserat på omvandlarens mjukvaruversioner.
✅ Begränsning stöds för firmware-versioner master v.2.05 och manager v.1.85 och tidigare.
⌛ Begränsning är under utveckling för firmware-versioner master v.2.06 och manager v.1.86 och senare.
H3-serien (non-pro, non-smart) använder ett annat kommunikationsprotokoll än H3 Pro och H3 Smart-serierna. Därför måste du vara mycket säker på att du väljer rätt typ när du anger enhetstyp i SmartgridOne Controller.
(*) Integrationen kan fungera för äldre firmware-versioner, men dessa är inte testade.

Standard modbus-adress, eller enhets-ID, är 247. Ha detta i åtanke när du söker efter en omvandlare. Du kan ändra minsta och största bussadresser som styrenheten söker igenom i sökparametrarna.
För korrekt ethernet-kabeldragning: Följ .
Du kan inte ansluta via WiFi-dongeln.
Omvandlaren kan anslutas till SmartgridOne Controller via RS485. Detta görs via anslutning [J] i bilden nedan.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Logger 485A / pin 1 | RS485 A | RS485_POS | RS485 A | TX+ |
| Logger 485B / pin 2 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |

| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| EMS 485A / pin 17 | RS485 A | RS485_POS | RS485 A | TX+ |
| EMS 485B / pin 18 | RS485 B | RS485_NEG | RS485 B | TX- |
| N/A | RS GND | GND | Not available | G |

Styrningen måste aktiveras via omvandlaren och elmätaren måste inaktiveras. Detta görs via displayen i menyn Feature Parm. Öppna först menyn Feature Parm enligt följande:



Använd displayen från Feature-sidan för att aktivera styrningen enligt stegen nedan:


Elmätaren måste inaktiveras. Styrningen kommer att tas över av SmartgridOne Controller. Därför ska elmätaren inte vara ansluten till omvandlaren utan till SmartgridOne Controller. För att inaktivera elmätaren i inställningarna, följ dessa steg:



Adress för omvandlaren kan också ställas in via displayen.

SmartgridOne Controller börjar som standard söka från adress 1. Att välja en lägre adress gör att din omvandlare snabbt hittas.
Om du har flera omvandlare är det viktigt att ställa in parallella adresser – varje omvandlare bör ha en unik adress.
Fjärrstyrning är aktiverad som standard, du behöver inte ändra några inställningar.
Att ändra omvandlaradressen (eller enhets-ID) görs på samma sätt som för H3 (se ovan).