SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvio rapidoAvvisi di sicurezza, manutenzione e note legaliCertificati
Configurazione dalla A alla Z
Controller
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di energia
ABBAccuenergyAcrelAlgodueAnexoBMR
Carlo Gavazzi
EM24EM111EM210EM511Serie EM300Serie EM500Serie VMU-S
ChargeeChintCompatibile con Smart GridContatore di energia configurato autonomamenteContatore Zendure P1Contatori energetici ShellyDati del contatore cloudDornscheidt
Eastron
Eneco
Eniris
EnjoyPowersFluviusFroniusHagerHomeWizardHuaweiIneproIskra
Janitza
JoulzKaifaKamstrupLandis+GyrLegrandLitiotM-BusMetcomP1ApiPhoenix-ContactPilotSagemcom
Schneider
Seneca S604SessySiemensSmappeeSocomecSolax
Solis
SunwodaTillquistVictronWeidmüllerWhatWattYouLessZiv
Inverter ibridi fotovoltaici e inverter per batterie
Nuove integrazioni
PLC
Pompa di calore
Stazione di ricarica per veicoli elettrici
InstallazioneLED di statoLicenzaLinee guida per il cablaggio e la connettivitàRete
Risoluzione dei problemi
Segnali esterni
Specifiche
Specifico per il cliente
Tempo di risposta al controllo
Toolbox
Tutorial video
DispositiviContatore di energiaCarlo Gavazzi

Contatore di energia Carlo Gavazzi EM511

logo

Dispositivi supportati

Device TypeModbus TCP (Ethernet)RS485
Carlo Gavazzi EM511❌✅
Image 1

Cablaggio

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Terminal 8 / A-RS485 ARS485_POSRS485 ATX+
Terminal 6 / B+RS485 BRS485_NEGRS485 BTX-
Terminal 7 / GNDRS GNDGNDNot availableG
Image 1

Configurazione

Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Last updated December 10, 2025Edit this page

EM210

Contatore di energia Carlo Gavazzi EM210

Serie EM300

Contatore di energia Carlo Gavazzi serie EM300

On this page

Dispositivi supportatiCablaggioRS485Configurazione