Inversores Delta
Dispositivos compatibles
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| Delta RPI | M6/M8/M10/M12/M15A/M20A/M30 | ❌ | ✅ | ✅ |
| H3/H5/H3A/H4A/H5A (not tested) | ||||
| M6A/M8A/M10A/M50A/M30A (not tested) |
Cableado
Los SmartgridOne Controller y los inversores Delta se comunican vía RS485.
RS485

| Configuración | Opciones |
|---|---|
| Velocidad en baudios | 2400 / 4800 / 9600 / 19200 (predeterminado) / 38400 |
| Bits de datos | 8 |
| Paridad | Ninguna |
| Bits de parada | 1 |
Configuración
Advertencia
NOTE: RS485 Device Addresses
- You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
- Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
- For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
Last updated December 10, 2025Edit this page