a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrydowe i Inwertery BateriiAPsystemsAteps BateriaBeauventBateria CCellpowerChisageDanfossDeltaInwertery PV, Hybrydowe i Akumulatory DET PowerDEYEDiehl-AkoInwertery DMEGCDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseWyposażenie EPInwertery ESYFortonaFraxFroniusGoodWeGotionGreener / AlfenHiteHithiumHypontechiWellJinkoKacoKehuaKostalMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcelSocomecSolarlogSolarMaxSolarwattSolaxSolintegSolplanetSunwaytechSunwodaSus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextXantrexZeversolar
Autarco
Solis
SpecyfikacjeDiody LED statusuCzas reakcji systemu kontrolnegoTutoriale wideoCertyfikatyLicencjaBezpieczeństwo, konserwacja i informacje prawne
UrządzeniaPV hybrid and battery inverters
logo

Obsługiwane urządzenia

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Inwertery hybrydowe jednofazowe (SG0XLP1-EU)SUN-3/3.6/5/6/7/7.6/8/10/12K❌✅❌
Inwertery hybrydowe trójfazowe (SG0XLP3-EU)SUN-3/4/5/6/8/10/12/14/15/16/18/20K
Inwertery hybrydowe wysokiego napięcia (SG0XHP3-EU)SUN-5/6/8/10/12/15/20/25/29.9/30/35/40/50/60/70/75/80K
Inwertery strunowe jednofazowe (G0XP1-EU)SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4/4.2/4.6/5/5.2/6/6.2/7/7.5/8/9/10/10.5K
Inwertery strunowe trójfazowe (G0XP3-EU)SUN-3/4/5/6/7/8/9/10/12/15/18/20/22/23/25/30/35/36/40/45/50/60/70/75/80/90/100/120/125/130/135/136K

Okablowanie

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Obraz 1
Obraz 1
Obraz 1

Konfiguracja

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Przejdź do “Ekran główny” >> “Ustawienia systemowe” >> “Funkcja zaawansowana.”

  • Numer Modbus SN powinien być ustawiony na dowolną liczbę między 1 a 247. Nie wybieraj 0!! Należy pamiętać, że jeśli na magistrali RS485 znajduje się wiele urządzeń, każde z nich powinno mieć unikalny numer. To jest adres.
  • Należy zaznaczyć “Slave”.
  • Tylko kiedy dodatkowy licznik jest bezpośrednio podłączony do inwertera, należy zaznaczyć “EX_meter For CT”. Jeśli istnieje tylko licznik równolegle z SmartgridOne Controller, powinno być to odznaczone.
  • Upewnij się, że następujące ustawienia są poprawne: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"
Obraz 1