SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvio rapidoAvvisi di sicurezza, manutenzione e note legaliCertificati
Configurazione dalla A alla Z
Controller
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di energia
Inverter ibridi fotovoltaici e inverter per batterie
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAPsystems
Autarco
Batteria AtepsBattlinkBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithiumHoymiles
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter fotovoltaici, ibridi e per batterie AnklousInverter fotovoltaici, ibridi e per batterie DET PoweriWellJinkoKacoKehuaKostal
Kstar
LibattionLONGiMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerOX-PowerPixiiPower-SonicPoweroadPylontechRCT PowerRefurbRegitecRenonRitarSAJSavSchneider SunEzySchucoSCUSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltTWSVaconVictronVolstoraWattsNextWeiheng
WHES
XantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
PLC
Pompa di calore
Stazione di ricarica per veicoli elettrici
InstallazioneLED di statoLicenzaLinee guida per il cablaggio e la connettivitàRete
Risoluzione dei problemi
Segnali esterni
Specifiche
Specifico per il cliente
Tempo di risposta al controllo
Toolbox
Tutorial video
DispositiviInverter ibridi fotovoltaici e inverter per batterie
logo

Dispositivi supportati

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Single Phase LV Hybrid Inverters (SG0XLP1-EU)SUN-3/3.6/5/6/7/7.6/8/10/12K❌✅❌
Three Phase LV Hybrid Inverters (SG0XLP3-EU)SUN-3/4/5/6/8/10/12/14/15/16/18/20K
Three Phase HV Hybrid Inverters (SG0XHP3-EU)SUN-5/6/8/10/12/15/20/25/29.9/30/35/40/50/60/70/75/80K
Single Phase String Inverters (G0XP1-EU)SUN-1/1.5/2/2.2/2.5/2.7/3/3.3/3.6/4/4.2/4.6/5/5.2/6/6.2/7/7.5/8/9/10/10.5K
Three Phase String Inverters (G0XP3-EU)SUN-3/4/5/6/7/8/9/10/12/15/18/20/22/23/25/30/35/36/40/45/50/60/70/75/80/90/100/120/125/130/135/136K

Cablaggio

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Pin 1 / Modbus-485_BRS485 ARS485_POSRS485 ATX+
Pin 2 / Modbus-485_ARS485 BRS485_NEGRS485 BTX-
Pin 3 / GND_485RS GNDGNDNot availableG
Image 1
Image 1
Image 1

Configurazione

Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Vai a “Schermata principale” >> “Impostazioni di sistema” >> “Funzione avanzata.”

  • Modbus SN deve essere impostato su un numero compreso tra 1 e 247. Non selezionare 0!! Nota che, se sono presenti più dispositivi sul bus RS485, a ciascuno deve essere assegnato un numero univoco. Questo è l'indirizzo.
  • Seleziona Slave.
  • “EX_meter For CT” deve essere selezionato solo quando un contatore aggiuntivo è collegato direttamente all'inverter. Se è presente solo un contatore in parallelo con il SmartgridOne Controller, deve essere deselezionato.
  • Assicurati che le seguenti impostazioni siano tutte corrette: "Max A Charge", "Max A Discharge", "Grid Charge Ampere"