iWell Cube Battery
Dispositivi supportati
| Device Type | Variants | Modbus TCP (Ethernet) | RS485 | Curtailment |
|---|---|---|---|---|
| iWell Cube Battery (Experimental) | Cube Series | ✅ | ❌ | ✅ |

Cablaggio
Il SmartgridOne Controller comunica con il sistema di batterie iWell Cube utilizzando Modbus TCP (Ethernet).
Collega la porta Ethernet (LAN) del sistema di batterie alla stessa rete del SmartgridOne Controller.
Info
RS485 Wiring
- For correct RS485 wiring: Follow the guidelines for RS485 wiring.
- If the wiring shown in the table below is incorrect, please let us know.
- There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
| Device | SmartgridOne Controller model OM1 | SmartgridOne Controller model IG8 | RS485-USB converter | RS485-Ethernet converter |
|---|---|---|---|---|
| Ethernet (TCP/IP) Port | RS485 A | RS485_POS | RS485 A | TX+ |
| Port Number | RS485 B | RS485_NEG | RS485 B | TX- |
| Connection Type | RS GND | GND | Not available | G |
Suggerimento
Suggerimento
Assicurati che sia il SmartgridOne Controller sia la batteria iWell Cube si trovino nella stessa subnet IP
(ad es. 192.168.1.xxx) e possano comunicare tramite la porta 1025.
Avviso
Avviso
L'interfaccia Modbus TCP di iWell Cube è attiva solo quando il sistema di batterie è acceso e inizializzato.
Non connetterti a unità inattive o durante gli aggiornamenti del firmware.