SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvio rapidoAvvisi di sicurezza, manutenzione e note legaliCertificati
Configurazione dalla A alla Z
Controller
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di energia
Inverter ibridi fotovoltaici e inverter per batterie
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAPsystems
Autarco
Batteria AtepsBattlinkBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentEVEFairlandFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithiumHoymiles
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter fotovoltaici, ibridi e per batterie AnklousInverter fotovoltaici, ibridi e per batterie DET PoweriWellJinkoKacoKehuaKostal
Kstar
LibattionLONGiMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerOX-PowerPixiiPower-SonicPoweroadPylontechRCT PowerRefurbRegitecRenonRitarSAJSavSchneider SunEzySchucoSCUSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltTWSVaconVictronVolstoraWattsNextWeiheng
WHES
XantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
PLC
Pompa di calore
Stazione di ricarica per veicoli elettrici
InstallazioneLED di statoLicenzaLinee guida per il cablaggio e la connettivitàRete
Risoluzione dei problemi
Segnali esterni
Specifiche
Specifico per il cliente
Tempo di risposta al controllo
Toolbox
Tutorial video
DispositiviInverter ibridi fotovoltaici e inverter per batterie
Dysun Energy

Dispositivi supportati

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Hybrid inverterDysun Hybrid✅✅❌
FlexAmpFlexAmp One 3.6K, 5K, 8K, 10K, 12K❌✅

Cablaggio

Dysun Hybrid

Modbus TCP

  • Collegare la porta LAN dell'inverter alla rete locale.
  • Porta predefinita: 502.
  • L'ID unità Modbus deve essere impostato tra 1–247 (valore predefinito 1).

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Impostazioni seriali:

ParametroValore
Baud rate9600 (predefinito) o come configurato nel menu dell'inverter
Bit di dati8
ParitàNessuna
Bit di stop1

FlexAmp

La serie FlexAmp comunica esclusivamente tramite RS485.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Impostazioni seriali:

ParametroValore
Baud rate9600 (predefinito)
Bit di dati8
ParitàNessuna
Bit di stop1

Configurazione

Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
  • Impostare l'indirizzo Modbus (ID slave) tra 1–247 nel menu del dispositivo.
  • Ogni dispositivo sul bus RS485 deve avere un indirizzo univoco.

Configurazione di FlexAmp

Durante la scansione del dispositivo o la configurazione manuale, verrà richiesto:

"Cosa è incluso nell'installazione?"

OpzioneQuando selezionarla
Pannelli solari e batteria (predefinito)Sono installati sia il fotovoltaico sia la batteria
Solo pannelli solariNon è presente alcuna batteria
Solo batteriaNon è presente alcun impianto fotovoltaico

Selezionare l'opzione corrispondente alla propria installazione. Una selezione errata comporterà misurazioni mancanti o non corrette.

Controllo

Dysun Hybrid

L'inverter supporta il controllo della batteria:

  • Modalità di carica: impostare la corrente di carica in ampere
  • Modalità di scarica: impostare la potenza di scarica come percentuale della potenza nominale
  • Quando il controllo smart grid è disabilitato, l'inverter torna al funzionamento autonomo
Attenzione
Attenzione

Sperimentale Le funzioni di controllo per Dysun Hybrid non sono state validate su hardware in funzione.


FlexAmp

La serie FlexAmp supporta la limitazione della produzione fotovoltaica — il controller può limitare in tempo reale la potenza massima di produzione solare.

  • Il limite di potenza attiva viene espresso come percentuale della potenza nominale.
  • Quando il controllo smart grid è disabilitato, il dispositivo torna alle impostazioni locali configurate (in genere con potenza in uscita non limitata).
  • La limitazione si applica alla produzione totale di tutte le stringhe fotovoltaiche collegate.
ModelloPotenza nominaleRisoluzione massima della limitazione
FlexAmp One 3.6K3 600 W1 W
FlexAmp One 5K5 000 W1 W
FlexAmp One 8k8 000 W1 W
FlexAmp One 10k10 000 W1 W
FlexAmp One 12k12 000 W1 W
Last updated May 6, 2026Edit this page

Dyness

Previous Page

Ecosourcen

Next Page

On this page

Dispositivi supportatiCablaggioDysun HybridModbus TCPRS485FlexAmpConfigurazioneConfigurazione di FlexAmpControlloDysun HybridFlexAmp