SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvertenze di sicurezza, manutenzione e legaliAvvio rapido
Cassetta degli attrezzi
Certificati
Configurazione dalla A alla Z
Controllore
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di Energia
Inverter Ibridi Fotovoltaici e per Batterie
a-TroniXABB, FIMERADS-TecAlphaESSAmpowrAngileApparecchiature EPAPsystems
Autarco
Batteria AtepsBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter Fotovoltaici, Ibridi e a Batteria DET PowerInverter Fotovoltaici, Ibridi e per Batterie AnklousiWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPrimaPylontechRCT PowerRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H fino a SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
Plc
Pompa di calore
Stazione di Ricarica EV
InstallazioneLED di statoLicenzaLinee guida per cablaggio e connettivitàRete
Risoluzione dei problemi
Segnali Esterni
Specifiche
Specifico del Cliente
Tempo di risposta del controlloVideo tutorial
DispositiviInverter Ibridi Fotovoltaici e per Batterie
Dysun Energy

Dispositivi Supportati

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Inverter ibridoDysun Hybrid✅✅❌
FlexAmpFlexAmp One 3.6K, FlexAmp One 5K❌✅

Cablaggio

Modbus TCP

  • Collegare la porta LAN dell’inverter alla rete locale.
  • Porta predefinita: 502.
  • L’ID unità Modbus deve essere impostato tra 1–247 (default ).

Dyness

Previous Page

Ecosourcen

Next Page

On this page

Dispositivi SupportatiCablaggioModbus TCPRS485ConfigurazioneConfigurazione Serie FlexAmpControlloDysun Hybrid
1

RS485

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485-ARS485 ARS485_POSRS485 ATX+
RS485-BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG

Impostazioni seriale:

  • Baud rate: 9600 (predefinito) o come configurato nel menu dell’inverter
  • Bit dati: 8
  • Parità: Nessuna
  • Bit di stop: 1

Configurazione

Avviso
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.
  • Impostare l’indirizzo Modbus (slave ID) tra 1–247 nel menu dell’inverter.
  • Ogni dispositivo sul bus RS485 deve avere un indirizzo univoco.
  • Per le migliori pratiche di cablaggio RS485, consultare le Linee guida per il cablaggio.

Configurazione Serie FlexAmp

Durante la scansione del dispositivo o la configurazione manuale, ti verrà chiesto:

"Cosa è incluso nell’installazione?"

  • Pannelli solari e batteria (predefinito)
  • Solo pannelli solari
  • Solo batteria

Seleziona l’opzione che corrisponde alla tua installazione per garantire un corretto rilevamento e monitoraggio dei dispositivi.

Controllo

Dysun Hybrid

L’inverter supporta il controllo batteria:

  • Modalità carica: Impostare la corrente di carica in ampere
  • Modalità scarica: Impostare la potenza di scarica in percentuale
  • Quando il controllo è disabilitato, l’inverter torna a funzionare in modo autonomo
Attenzione
Attenzione

Sperimentale Le funzionalità di controllo per Dysun Hybrid non sono state validate su hardware reale.