SmartgridOne logo
SmartgridOne logo
Accessori
AppAvvio rapidoAvvisi di sicurezza, manutenzione e note legaliCertificati
Configurazione dalla A alla Z
Controller
Dispositivi
Caldaia
Carichi commutati
Cloud
Contatore del gas
Contatore dell'acqua
Contatore di energia
Inverter ibridi fotovoltaici e inverter per batterie
a-TroniXABB, FIMERADS-TecAforeAlphaESSAlpvoltAmpowrAngileAPsystems
Autarco
Batteria AtepsBattlinkBeauventC-BatteryCellpowerChisageDanfossDeltaDEYEDiehl-AkoDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentEVEFairlandFortona
Foxess
FoxESS GMAXFoxESS Serie HFoxESS serie R
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithiumHoymiles
Huawei
Hypontech
Hyxipower
Inverter DMEGCInverter ESYInverter fotovoltaici, ibridi e per batterie AnklousInverter fotovoltaici, ibridi e per batterie DET PoweriWellJinkoKacoKehuaKostal
Kstar
LibattionLONGiMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerOX-PowerPixiiPower-SonicPoweroadPylontechRCT PowerRefurbRegitecRenonRitarSAJSavSchneider SunEzySchucoSCUSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunsynkSunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltTWSVaconVictronVolstoraWattsNextWeiheng
WHES
XantrexZendure SolarFlowZetaraZeversolar
Nuove integrazioni
PLC
Pompa di calore
Stazione di ricarica per veicoli elettrici
InstallazioneLED di statoLicenzaLinee guida per il cablaggio e la connettivitàRete
Risoluzione dei problemi
Segnali esterni
Specifiche
Specifico per il cliente
Tempo di risposta al controllo
Toolbox
Tutorial video
DispositiviInverter ibridi fotovoltaici e inverter per batterieFoxess
logo

Dispositivi supportati

Device TypeModbus TCP (Ethernet)RS485CurtailmentMinimum device firmware version
H3 (Non-Pro, Non-Smart): → ❗See note below ❗❌✅❗(see below)Master: 2.05, Manager: 1.85 (*)
H3 AIO (All-In-One)✅❌Master: 1.33, Manager: 1.37 (*)
H3-Smart⌛ (in development)Master: 1.25, Manager: 1.14 (*)
H3-ProMaster: 1.62, Manager: 1.34 (*)
H1(experimental, requires testing)Master: 1.70, Manager: 1.78 (*)
H1-G2⌛ (in development)Master: 1.40, Manager: 1.54 (*)
P3-SH✅ (experimental)✅ (experimental)Master: 1.62, Manager: 1.34 (*)
Attenzione
Attenzione

H3 (Non-Pro, Non-Smart)

L'H3 (Non-Pro, Non-Smart) utilizza protocolli di comunicazione diversi a seconda della versione "master" e della versione "manager" dell'inverter. Scegliere l'integrazione corrispondente in base alle versioni software dell'inverter.

✅ Il curtailment è supportato per le versioni firmware master v.2.05 e manager v.1.85 e precedenti.

⌛ Il curtailment è in fase di sviluppo per le versioni firmware master v.2.06 e manager v.1.86 e successive.

Avviso
Avviso

La serie H3 (non-pro, non-smart) utilizza un protocollo di comunicazione diverso rispetto alle serie H3 Pro e H3 Smart. Pertanto, quando si seleziona il tipo di dispositivo nel SmartgridOne Controller, è necessario essere assolutamente certi di selezionare il tipo corretto.

Nota
Nota

Versioni firmware supportate

(*) L'integrazione potrebbe funzionare con versioni firmware precedenti, ma queste non sono state testate.

Image 1

Cablaggio

Avviso
Avviso

L'indirizzo modbus predefinito, o ID dispositivo, è 247. Tenerne conto durante la scansione di un inverter. È possibile modificare gli indirizzi bus minimo e massimo che il controller analizzerà nei parametri di scansione.

Ethernet

Per un cablaggio Ethernet corretto: seguire le linee guida per il cablaggio Ethernet.

Avviso
Avviso

Non è possibile collegarlo tramite il dongle WiFi.

RS485

L'inverter può essere collegato al SmartgridOne Controller tramite RS485. Il collegamento viene effettuato attraverso la connessione [J] nell'immagine seguente.

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
Logger 485A / pin 1RS485 ARS485_POSRS485 ATX+
Logger 485B / pin 2RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

RS485 H3 Pro

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
EMS 485A / pin 17RS485 ARS485_POSRS485 ATX+
EMS 485B / pin 18RS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG
Image 1

Configurazione per H3 (Non-Pro, Non-Smart) e H1-G2

1. Attivazione del monitoraggio e della gestione dell'inverter

Il controllo deve essere attivato tramite l'inverter e il contatore deve essere disattivato. Questa operazione viene eseguita tramite il display, nel menu Feature Parm. Per prima cosa, aprire il menu Feature Parm come segue:

  1. Accedere al menu.
Image 1
  1. Inserire la password. Il valore predefinito è 0000.
Image 1
  1. Selezionare Settings.
Image 1
  1. Selezionare Feature Parm.

2. Attivazione del controllo remoto

Utilizzare il display nella pagina Feature per attivare il controllo, seguendo i passaggi riportati di seguito:

  1. Selezionare Remote control.
Image 1
  1. Impostarlo su Enable.
Image 1

3. Disattivazione del contatore

Il contatore deve essere disattivato. Il controllo sarà preso in carico dal SmartgridOne Controller. Pertanto, il contatore non deve essere collegato all'inverter, ma al SmartgridOne Controller. Per disattivare il contatore nelle impostazioni, procedere come segue:

  1. Tornare alla pagina Feature.
  2. Selezionare Meter1.
Image 1
  1. Selezionare Set.
Image 1
  1. Impostarlo su Disable.
Image 1

4. Impostazione dell'indirizzo dell'inverter

È possibile impostare l'indirizzo dell'inverter anche tramite il display.

  1. Accedere al menu Settings come descritto in precedenza.
  2. Selezionare Communication.
  3. Selezionare RS485.
  4. Selezionare Device ID.
  5. Impostare l'ID dispositivo sull'indirizzo desiderato. Se si collegano più dispositivi allo stesso bus RS485, è necessario assegnare a ciascuno un indirizzo univoco.
Image 1
Suggerimento
Suggerimento

Scansione più rapida

Il SmartgridOne Controller avvia per impostazione predefinita la scansione dall'indirizzo 1. Scegliendo un indirizzo più basso, l'inverter verrà trovato più rapidamente.

Avviso
Avviso

Più inverter

Se sono presenti più inverter, è importante impostare gli indirizzi paralleli: ogni inverter deve avere un indirizzo diverso.

Configurazione per H3-smart e H3-Pro

Il controllo remoto è attivato per impostazione predefinita; non è necessario modificare alcuna impostazione.

La modifica dell'indirizzo dell'inverter (o dell'ID dispositivo) può essere effettuata nello stesso modo dell'H3 (vedere sopra).

Last updated March 10, 2026Edit this page

FoxESS GMAX

Previous Page

FoxESS serie R

Next Page

On this page

Dispositivi supportatiH3 (Non-Pro, Non-Smart)Versioni firmware supportateCablaggioEthernetRS485RS485 H3 ProConfigurazione per H3 (Non-Pro, Non-Smart) e H1-G21. Attivazione del monitoraggio e della gestione dell'inverter2. Attivazione del controllo remoto3. Disattivazione del contatore4. Impostazione dell'indirizzo dell'inverterScansione più rapidaPiù inverterConfigurazione per H3-smart e H3-Pro