a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps BatteryBeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersFortonaFraxFroniusGoodWeGotionGreener / AlfenHiteHithiumHypontechiWellJinkoKacoKehuaKostalMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcelSocomecSolarlogSolarMaxSolarwattSolaxSolintegSolplanetSunwaytechSunwodaSus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextXantrexZeversolar
Autarco
Solis
SpecificationsStatus LEDsControl response timeVideo tutorialsCertificatesLicenseSafety, maintenance and legal notices
DevicesPV hybrid and battery inverters
logo

Energreen Inverters

Supported Devices

Device TypeModbus TCP (Ethernet)RS485Curtailment
Stor✅✅✅
PV Max
Hybrid

Wiring

The SmartgridOne Controller and the Dyness inverters communicate via RS485 or Ethernet.

Ethernet

For correct ethernet wiring: Follow the the guidelines for ethernet wiring.

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
ARS485 ARS485_POSRS485 ATX+
BRS485 BRS485_NEGRS485 BTX-
N/ARS GNDGNDNot availableG

Configuration

Ensure that modbus is enabled:

  1. From the main page go to "Device"
  2. Click "Powerhouse Settings"
  3. Enable "Modbus TCP Server Enable"
Energreen Modbus

Ensure that the inverter has been set to Remote EMS Mode:

  1. From the main page go to "System"
  2. Click the three dots next to the installation namespace
  3. Click "System Settings"
  4. Click "Operational Mode"
  5. Select "Remote EMS Mode"
Energreen Mode

Disable any grid limits:

  1. From the main page go to "System"
  2. Click the three dots next to the installation namespace
  3. Click "System Settings"
  4. Under "Operational Parameters" disable "Export Limitation" and "Import Limitation"
  5. Set "Grid Connection Point Reserve Power Control Method" to "Power Per Phase"
Energreen Limits
NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.