SmartgridOne logo
SmartgridOne logo
Accessories
AppCertificates
Configuration from A to Z
Control response timeController
Customer Specific
Devices
Boiler
Cloud
Energy Meter
Ev Charging Station
Gas Meter
Heat Pump
New integrations
Plc
Pv Hybrid And Battery Inverters
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps Battery
Autarco
BeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersEVEFortona
Foxess
FraxFroniusGoodWeGotionGreener / Alfen
Growatt
HiteHithium
Huawei
Hypontech
Hyxipower
iWellJinkoKacoKehuaKostal
Kstar
MarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSE2200H till SE6000HSessySigenergySinexcel
Sma
Socomec
Sofar
Solaredge
SolarlogSolarMaxSolarwattSolaxSolinteg
Solis
Solplanet
Sungrow
SunwaytechSunwoda
Sunwoda
Sus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextWeihengXantrexZendure SolarFlowZetaraZeversolar
Switched Loads
Water Meter
External Signals
InstallationLicenseNetworkQuick StartSafety, maintenance and legal noticesSpecificationsStatus LEDs
Toolbox
Troubleshooting
Video tutorialsWiring & connectivity guidelines
DevicesPv Hybrid And Battery Inverters
Zetara Logo

Zetara Inverters

Zetara offers high-performance energy storage solutions, primarily featuring the Inspiration-T series. These devices are whitelabeled versions of the AlphaESS Smile series, providing robust hybrid inverter capabilities for residential and commercial energy management.

Supported Devices

The Zetara Inspiration-T is a hybrid system supporting both PV and Battery integration.

Device TypeVariantsModbus TCP (Ethernet)RS485Curtailment
Inspiration-TInspiration-T Hybrid✅✅✅
Note
Note

The Zetara Inspiration-T uses the AlphaESS Smile communication protocol (V1.45). When configuring the device, it may be identified as an AlphaESS-compatible unit.

Communication Options

Ethernet (Modbus TCP)

The preferred method for connecting the Inspiration-T to the Controller.

  • Default Port: 502
  • Protocol: Modbus TCP

RS485 (Modbus RTU)

For installations where Ethernet is unavailable:

  • Protocol: Modbus RTU
  • Baud Rate: 9600 (default)

Wiring

Ethernet Connection

For correct ethernet wiring, follow the guidelines for ethernet wiring.

RS485 Connection

For models supporting RS485:

Info
RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 ARS485 ARS485_POSRS485 ATX+
RS485 BRS485 BRS485_NEGRS485 BTX-
GNDRS GNDGNDNot availableG
  • Use shielded twisted pair (STP) cable.
  • Maintain proper polarity (A to A, B to B).

Configuration & Commissioning

Critical Installation Requirements

Important
Important

Grid Meter Requirement A compatible grid meter must be installed and correctly communicating with the Zetara inverter. If the grid meter is missing or offline, the device will not follow power setpoints (charge/discharge commands) from the Controller.

Caution
Caution

PV Input Detection During the initial device scan, a detectable voltage must be present on each PV input you wish to monitor. If a PV string is not producing voltage (e.g., during night-time or if disconnected), the driver will not add that specific module to the system tree.

Device Components

When scanned, the Inspiration-T will present as a composite device:

  • Inverter: The primary management unit.
  • PV Total: Aggregated data from all active strings (up to 6).
  • Battery Input: Real-time data for SOC and battery power.

Zendure SolarFlow

Previous Page

Zeversolar

Next Page