SmartgridOne logo
SmartgridOne logo
Quick StartInstallationNetworkWiring & connectivity guidelinesApp
OverviewNew integrations
a-TroniXABB, FIMERADS-TecAforeAlphaESSAmpowrAngileAnklous PV, Hybrid and Battery InvertersAPsystemsAteps BatteryBeauventC-BatteryCellpowerChisageDanfossDeltaDET Power PV, Hybrid and Battery InvertersDEYEDiehl-AkoDMEGC InvertersDynessDysun EnergyEcosourcenEenovanceElecnovaEnbrilionEnergreenEnerlutionEnjoyPowersEnphaseEP EquipmentESY InvertersFortonaFraxFroniusGoodWeGotionGreener / AlfenHiteHithiumHypontechiWellJinkoKacoKehuaKostalMarstekMastervoltMidTeQMotomaOctave EnergyOmniPowerPixiiPower-SonicPoweroadPylontechRefurbRegitecRenonRitarSAJSchneider SunEzySchucoSCUSessySigenergySinexcelSocomecSolarlogSolarMaxSolarwattSolaxSolintegSolplanetSunwaytechSunwodaSus-PowerTeclomanTeploreTesvoltVaconVictronVolstoraWattsNextXantrexZeversolar
Autarco
APIData Manager M
Sunny BoySunny Tripower
Solis
SpecificationsStatus LEDsControl response timeVideo tutorialsCertificatesLicenseSafety, maintenance and legal notices
DevicesPV hybrid and battery invertersSMASolar
Logo

Supported Devices

Device TypeVariantsModbus TCP (Ethernet)CurtailmentMinimum device firmware version
Sunny BoySunny Boy 1.5 (SB1.5-1VL-40)✅✅4.03.07.R
Sunny Boy 2.0 (SB2.0-1VL-40)
Sunny Boy 2.5 (SB2.5-1VL-40)
Sunny Boy 3.0 (SB3.0-1AV-40)
Sunny Boy 3.6 (SB3.6-1AV-40)
Sunny Boy 4.0 (SB4.0-1AV-40)
Sunny Boy 5.0 (SB5.0-1AV-40)
Sunny Boy 3.0 (SB3.0-1AV-41)
Sunny Boy 3.6 (SB3.6-1AV-41)
Sunny Boy 4.0 (SB4.0-1AV-41)
Sunny Boy 5.0 (SB5.0-1AV-41)
Sunny Boy 6.0 (SB6.0-1AV-41)
Sunny Boy 3000 TL-21
Sunny Boy 3600 TL-21
Sunny Boy 4000 TL-21
Sunny Boy 5000 TL-21

Wiring

For correct ethernet wiring: Follow the the guidelines for ethernet wiring.

Configuration

  1. Connect with your computer on the same LAN network as the SMA Sunny Boy.
  2. In your web browser, surf to the IP address of the device.
  3. Log in as "Installer."
Image
  1. Go to the device parameters tab.
Image
  1. Click "Edit parameters."
  2. Open the "External Communication" dropdown menu → "Modbus" → "TCP server."
  3. Set "Activated" to "Yes" and "Port" to "502".
  4. At the top of the page, click "Save all."
Image
Image

Connection to the Controller

You then need to connect the device to the controller, for that follow this guide : Adding a device.